Industries > Ind Refrigeration Manufacturers

Refrigeration Systems

Configure the refrigeration system from load conditions to compressor rack

Turn box dimensions, product load, ambient conditions, and site requirements into a governed equipment configuration — without rebuilding the calculation in spreadsheets.

Mercura CPQ executes manufacturer-validated formulas and selection rules. It does not ship as a universal refrigeration engineering package. Regulatory review may still be required for refrigerant and site compliance.

Illustrative configuration

From room conditions to a valid refrigeration system

Box dimensions, ambient, and operating profile become load, evaporator, rack, and pipe run under manufacturer-defined formulas — not a universal refrigeration package.

Refrigeration system configurator

Room conditions → load → evaporator → rack · manufacturer-defined formulas

Step 1 of 8Illustrative Mercura configuration

Application

Illustrative Mercura configuration. Load figures are demo formulas. Regulatory review may be required for refrigerant and site rules.

System view

How room conditions become a valid refrigeration system

Cold room → evaporator → pipe run → rack → condenser — one commercial configuration.

  1. 01

    Application

    Cold room, freezer, process, or distribution duty.

  2. 02

    Room conditions

    Dimensions, target temperature, ambient, door openings.

  3. 03

    Heat load

    Transmission, product, infiltration, misc — manufacturer formulas.

  4. 04

    Evaporator

    Capacity must meet or exceed calculated load.

  5. 05

    Compressor rack

    Ambient derate can move a rack from OK to review.

  6. 06

    Refrigerant & pipe run

    Encoded availability and line-length dependencies.

  7. 07

    Valid system + quote

    Complete package priced from the same session.

Why quoting gets difficult

Load, ambient, refrigerant and piping are connected

Breaking them into separate spreadsheets is how undersized racks ship.

Heat load is not a single number

Transmission, product, infiltration, and occupancy all move with room geometry and door traffic.

Ambient changes capacity

A rack that is fine at 32°C design may need review at 42°C extreme — encoded as manufacturer derate rules.

Refrigerant and pipe runs

Availability and charge-related dependencies follow manufacturer / regulatory rules encoded in Mercura — not automatic compliance certification.

Before / after

How the refrigeration quote gets built

Before

  • Customer gives cold-room dimensions
  • Engineer calculates load offline
  • Evaporator sized, then ambient checked
  • Rack selected, refrigerant validated
  • Piping calculated last
  • Spreadsheet quote assembled

With Mercura CPQ

  • Application inputs captured in sales
  • Manufacturer formulas run in the configuration
  • Equipment sized against load and ambient
  • Incompatible options blocked
  • Full system priced
  • Quote generated from the valid configuration

Capabilities

What Mercura carries for refrigeration selection

Load, evaporator, rack, and refrigerant rules belong in the quote — these capabilities carry them.

See your refrigeration sizing and selection logic in Mercura

Bring load formulas, evaporator/rack tables, and refrigerant option rules. We will show how they run as guided configuration for sales and applications.

Request a CPQ demo